Research·Report NR-02·13 September 2026

A false regime and its correction: the cortical microcircuit and its metabolism

A cortical column considered validated worked only in the first second. The defect was in the single neuron, and connecting the network to energy revealed a second limitation.

Gioele ChiarolanzaNadirion

Validated, open limits 2 test benches · 19 failed network repairs · confirmation on unseen seeds
5/5column criteria at steady state after the fix, on seeds 6–11 too
19attempts to repair the network, all failed: the defect was in the neuron
5/6criteria of the metabolism coupled to the network
0/5depolarisation block attempted and not adopted

Summary

The spiking cortical column with active dendrites was considered validated with 5 criteria out of 5. Coupling it to metabolism revealed that the result had been measured in the first second, before the network reached its regime: at steady state the column slid into a hyperactive state that sustained itself. Nineteen repair attempts at the network level failed. A chain of hypotheses written in advance located the defect in the single neuron: the calcium/NMDA dendritic plateau had no termination mechanism and, once switched on, stayed on for ever. A potassium current activated by the plateau corrects it; with a declared scan of three parameters the column again passes 5 criteria out of 5 at steady state, also on seeds never used in the choice. The metabolism coupled to the corrected column passes 5 criteria out of 6 and closes the energy–network loop; two extensions (depolarisation block and ischaemia timing) failed and were not adopted.

1Why it matters

Phase 2 of the organism, with populations of spiking neurons, rests on this column. Test F5 of the theory, which asks whether the organism's defence preserves inhibition when energy fails, requires a network coupled to metabolism. A non-stationary network would have produced results that depend only on when one looks.

2The model

The column uses Izhikevich neurons with conductance-based synapses, integrated every 0.5 ms: excitatory pyramidal cells with 4 active dendritic branches (AMPA, NMDA and calcium plateau) and two classes of inhibitory interneurons, PV and SST. The assemblies have reinforced connectivity within them, as in the model of Litwin-Kumar and Doiron (2012). The key criterion, C4, requires a brief stimulus to switch on localised persistent activity in the stimulated assembly.

3How we found the defect

stepresult
coupling to metabolisminterneuron rate 40.5 Hz, above the limit: the column is not stationary
same criteria at steady state (3 s of transient discarded)3 out of 5: localised persistent activity in 0 assemblies out of 6; the "validated" status is withdrawn
12 network variants (input, connections, NMDA, clustering, PV)none restores C4
assembly-specific inhibition (Rost and colleagues, 2018), 7 variantssaturation or the same active state; not adopted
plateau hypothesis (three hypotheses written in advance)two confirmed, one refuted: cutting every input makes firing rise
isolated neurons30 ms of stimulus lock the plateau on for ever: the soma fires at about 556 Hz without any input
diagnosisin the real neuron the plateau lasts tens or hundreds of ms and ends through potassium conductances (Schiller and colleagues, 2000; Major and colleagues, 2008)
potassium fix, unchanged configuration185 ms plateau, no locking; the network becomes silent or bistable: 3 out of 5
declared scan of 20 variants on seeds 0–2external input, clustering and NMDA weight chosen
run 25 out of 5 at steady state
“validated” column (first second) same criteria at steady state (V2-STEADY) K⁺ fix run 1 V2-PLATEAU run 2 unseen seeds 6–11 0 1 2 3 4 5 6 count 5/5 3/5 3/5 5/5 0/6 5/6 5/6 V2 criteria passed (of 5) assemblies with localised persistent activity (of 6)
Figure 1. Criteria passed and assemblies with localised persistent activity along the diagnostic chain. The initial "5 out of 5" was measured in the first second; at steady state the column drops to 3 out of 5 and no assembly keeps localised activity. After the plateau fix and the parameter scan the column is back to 5 criteria out of 5, with localised activity in 5 assemblies out of 6, also on seeds 6–11 never used to choose the parameters.

The fix adds to the dendritic branch a current g·k·(E_K − v), with a variable k that follows the plateau with a time constant of 150 ms, conductance 2.0 and potassium reversal potential at −90 mV. The historical benches remain fixed to the previous model so that they can be reproduced.

4The metabolism coupled to the network

The metabolic substrate (ATP, ADP, cerebral flow, astrocyte–neuron shuttle) existed but was not connected to any network. We coupled it to the corrected column with three compartments, pyramidal, PV and SST, and different energy costs per population taken from the literature: 21% of the signalling budget to action potentials and 50% to postsynaptic receptors (Howarth, Gleeson and Attwell, 2012); a cost per spike for PV cells 1.6 times that of pyramidal cells (Carter and Bean, 2009). When ATP falls, vitality drops, the sodium–potassium pump fails and synaptic release is reduced.

criterionoutcome
Q0 isolationpassed: with the feedback off, 6238 spikes identical bit for bit
Q1 stable restpassed: ATP 2.82–2.94 mM, drift at most 0.46%
Q2 balancepassed: maximum error 5.0 × 10⁻¹⁶
Q3 demand → supplyfailed: total demand rises by 5–7% against the 10% required
Q4 supply → networkpassed: during hypoxia 105.7 Hz with the feedback against 8.5 without
Q5 auditpassed

Criterion Q3 fails because of how it was written, not because of the model: baseline consumption is about two thirds of the total, so +6% of the total corresponds to about +20% of signalling. The criterion was not rewritten.

pyramidal E PV SST 0 5 10 15 20 steady-state rate (Hz) ~6 Hz ~13 Hz ~19 Hz Corrected column, steady state energy feedback on feedback off 0 20 40 60 80 100 120 rate during hypoxia (Hz) 105.7 Hz 8.5 Hz Hypoxia of 20–25 s
Figure 2. Left, the steady-state rates of the corrected column by population. Right, the network rate during 20–25 s of hypoxia with the energy feedback on and off: when ATP falls the network really changes, but in the wrong direction (see the critical limitation). Values from the logs of the V2-PLATEAU and V2-ENERGY-P2 benches.

5The critical limitation: neurons that speed up instead of stopping

With ATP exhausted the model neurons fire at hundreds of hertz, whereas real neurons go into depolarisation block and stop firing. We tried to fix this twice:

Test F5 remains blocked until we have a neuron with a biophysical anoxic block, for example with sodium inactivation based on conductances or ion concentrations (Kager and colleagues, 2000).

6What it shows and what it does not

It shows that the column now has a physiological stationary regime, that the defect was cellular and not in the network, and that the energy–network loop is exact and isolated, with per-population costs grounded in the literature.

It teaches a rule of method that we have applied to every module since: every criterion is measured at steady state, with the transient declared and discarded. It is a lesson the project had to relearn later, for example with the spiking workspace (NR-05).

It does not show quantitative fidelity to cortical data: the margins on persistent activity and on the gamma band are thin. It says nothing about the order in which populations fail during hypoxia, which depends on the artefact of firing at zero ATP.

References

How to cite

Chiarolanza, G. (2026). A false regime and its correction: the cortical microcircuit and its metabolism. Nadirion, research report NR-02, 13 September 2026. https://nadirion.eu/en/research/microcircuit-metabolism/

Nadirion technical report, not peer-reviewed. The criteria of every test were written before running it; negative results are reported like positive ones. The tests measure functional roles.